Click to enlarge image
|
Model Number |
GSS Series |
GSS Series
Specification
| Model |
GSS5 |
GSS7 |
GSS11 |
| Type |
Rotary Twin Screw, Oil-Cooled, Single Stage |
| Discharge Pressure |
kgf/㎠ G |
8 |
9.5 |
12 |
8 |
9.5 |
12 |
8 |
9.5 |
12 |
| Discharge Air Volume |
㎥/min |
0.80 |
0.71 |
0.59 |
1.12 |
1.00 |
0.82 |
1.70 |
1.58 |
1.38 |
| Driving System |
- |
Belt |
| Cooling System |
- |
Air Cooled |
| Discharge Air Temperate |
°C
|
Ambient Temp + 15°C less |
| Discharge Pipe Dia |
A (inch) |
20A(3/4") |
| Dimension |
L |
mm |
670 |
690 |
| W |
mm |
980 |
1,030 |
| H |
mm |
800 |
850 |
| Weight |
kg |
250 |
270 |
290 |
| Lubrication Oil Volume |
ℓ
|
6 |
| Motor |
Rated Output |
Kw / HP |
5.5/7.5 |
7.5/10 |
11 / 15 |
| Starting System |
- |
Star-Delta |
| Voltage |
V |
220 / 380 / 440 |
| Frequency |
Hz |
50 / 60 |
- Above specification can be changed without advance notice for improvement of performance.
- Outlet amount of air is value converting to inlet condition.
Controller

The Best Stability
The Multifunction Control is Based on Simplicity to Ensure Trouble Free Long Life. The Operating Mode can be Easily Changed to suit the Demand.
Display Particulars
- Discharge Air Pressure
- Discharge Air Temperature
- Total Running Time
- Main & Fan Motor Trip
- High Temperature Trip
- Start/stop Button
Simple Operating Panel
AIRPLUS Control Panel is Designed to Give the Maximum Satisfaction Through the Minimum Operation, Based on the Experience that Various Function cause Various Trouble. AIRPLUS Control Panel Provides an Essential Function to Meet Varying Site Condition Completely.
P&ID Composition

|
|
|
|
| |
|
|
|